Liberia Maritime Authority published the Guidance on Machinery Space Deficiencies

Liberia Maritime Authority published the Guidance on Machinery Space Deficiencies.

The purpose of this Advisory is to alert you on the recent focused trend by various Port State Control regimes during the inspection of Machinery Spaces.

We have seen an increased focus on the proper operation of firefighting equipment and cleanliness of Machinery Spaces.

Specifically, the following items are consistently noted by Port State Control Officers:

  1. Engine Room Water Mist system set in “Manual” mode.
  2. Fuel Oil Quick Closing valves blocked open by use of wedges or wires.
  3. Pipes insulation laggings wrongly installed, soaked in Fuel Oil, or missing.
  4. Excessive Fuel, Oil accumulation, and Lubrication Oil leaks in Machinery Spaces, Auxiliary Engines, Steering Gear Room, or Purifier Room.
  5. Inoperable Fixed Gas Detection systems, missing ship procedures on how to test the system, lack of crew knowledge on the proper operation of fixed gas detection systems, ships lacking the appropriate span gas to test the system or not having any span gas available, and missing specific testing equipment (adapter to connect to the sample point, appropriate regulator to hook up to the span gas, inflatable bags to hold the gas).

The Liberian Administration encourages Owners, Operators, and their Masters and Chief Engineers to take this Marine Advisory into account during the normal operation of their vessels and ensure the following steps and checks are included in the proper conduction of the Engineering Watches and Planned Maintenance:

  1. Engine Room Water Mist Systems must be readily available for immediate use and in good working order. The activation switch on the system control panel must be set to “Remote” or “Automatic.” Precaution shall be taken to prevent the nozzles from becoming clogged by impurities in the water, regular checks must be carried out to identify corrosion of piping, nozzles, valves, and pump.
  2. Quick Closing Valves are positive shut-off valves that are designed to isolate oil tanks in the event of a fire and also prevent fueling of a fire in circumstances where system piping and components are compromised. Such valves must always be free to operate, and manual wire activators and/or hydraulic systems must be kept under close examination and tested regularly. Under no circumstance shall a valve operation be hindered by fitting wedges or wires to preclude the activation. A maintenance plan should be in place, including technical manuals containing diagrams and information that describe the system components, required spare parts, operation, maintenance and repair. All engine department personnel should be able to identify the location of each valve, the respective remote closure, and how to close them locally and remotely in an emergency.
  3. Insulation Lagging should be inspected regularly. Inspection should include looking for signs of cracking, distortion, or any damage or signs of a hot spot. Evidence of leaks shall be acted upon with celerity and corrected to prevent the possibility of fire. Equipment hot spots should be identified and insulated to prevent the creation of areas that could ignite a fire in case of sprays or leaks in the system.
  4. Fuel and Lubricant leaks can easily lead to a fire or an explosion due to their highly flammable nature or create pollution and hazardous situations. Leaks from Fuel Pumps, Main Engines, Generators, and Steering Gears shall be corrected immediately. Adhering to a robust Preventative Maintenance System ensures that repairs are carried out prior to the development of leaks that can lead to fires, and pollution and are a common reason for ships to be detained by Port State Control. The following areas have been known for leaks and oil accumulation:

    a. In the vicinity of double jacket pipes on top of the main engine
    b. Accumulation on top of the main engine
    c. Oil leaks dripping down the main engine crack case
    d. Bilge area around the lube oil pumps behind the main engine
    e. Under the rocker covers of auxiliary engines
    f. Fuel filters for the auxiliary engine
    g. Underneath the auxiliary engine platforms
    h. Underneath the lube oil/fuel oil purifiers
    i. Oil-soaked lagging in the purifier room
    j. Shaft penetrations of any fuel/oil pumps
    k. Valves throughout any fuel/oil piping
    l. Oil-soaked lagging throughout any fuel/oil piping
    m. Sides/bulkheads of tanks in the engine room
  5. Fixed gas detection systems are vital to ensure that the engine room and cargo block are not at risk for cargo vapors that could pose harm to the crew, ship, and the environment. Additionally, the proper operation and testing of the system demonstrates that the system is functioning as designed. Finally, using and having the appropriate span gas on board demonstrates that the crew is actively verifying that the system is operational.

Rectification and prevention of these situations are vital for the safe operation of any vessel.

This document was published on 19 September 2023 and supersedes Marine Advisory 06/2023.


For more information, please see the document below (available only to subscribers):


Guidance on Machinery Space Deficiencies